Skip to main content

Part of the ISS family of companiesSafe. Smart. Reliable.

ISSKopplMickie Service Company
Two red fabricated concrete pressure pipe components with black flanged ends, set on a wooden pallet outside a shop

Concrete pressure pipe

PCCP to ductile iron adapter: what has to match before new pipe ties into a concrete main

A PCCP to ductile iron adapter is built around the concrete pipe you actually have. Here is what it has to match, why field data beats drawings, and what to send Koppl.

Koppl blog

Concrete pressure pipe

· 6 min read

All blog posts

If you manage a water main for a utility, a city, a hospital or a large facility, a PCCP to ductile iron adapter usually comes up for one of two reasons. A damaged section of concrete pressure pipe has to come out and ductile iron is going in its place. Or a new ductile iron line has to tie into a concrete main that stays in the ground. The short answer is that the connection can be made. But the adapter is built around the pipe you actually have, not pulled off a shelf. Koppl fabricates transition adapters in-house as part of its concrete pressure pipe repair work.

When a PCCP to ductile iron adapter comes up

Koppl's concrete pressure pipe repair page lists these among its common applications:

  • Pipe-section replacement, where a damaged piece of concrete pipe is cut out and replaced
  • Valve replacement on a concrete main
  • DIP, PVC, HDPE and PCCP transitions, where new pipe of another material meets the existing concrete line
  • Leak and joint repair, and emergency welding and repair

Each of these can leave you with concrete pipe on one side and ductile iron on the other. If the job is a new branch on a live concrete main rather than a transition, see hot tapping concrete pressure pipe. If a joint is leaking but the pipe itself can stay, start with what to plan first for concrete pipe joint repair.

Why a standard coupling is not the default answer

Concrete pressure pipe is built in layers, and the pipe type changes what sits under the coating. Koppl supports bar-wrapped pipe (B303), prestressed concrete cylinder pipe (L301) and embedded-cylinder pipe (E301). Each has its own wire and cylinder configuration. That is why identifying the pipe comes before choosing the adapter.

A ductile iron pipe maker makes a similar point. McWane Ductile notes that many pipe types require custom-made couplings to connect to ductile iron, and that in some cases the pipe manufacturer may need to make the adapter.

Pipe identity is not always what the records say. In one engineering forum thread on connecting ductile iron to concrete pressure pipe, a utility engineer started out believing the line was reinforced concrete pressure pipe. Later testing suggested it might be prestressed concrete cylinder pipe instead. The adapter design depends on which one is in the ground.

What the adapter has to match

Koppl's products page describes what a useful fabrication request covers. For a transition between concrete pressure pipe and ductile iron, those inputs fall into three groups.

The concrete pipe

  • Pipe type, with its wire and cylinder configuration
  • Pipe material, outside diameter, nominal size and wall thickness
  • Coating, lining, reinforcement, corrosion and surface condition

The new connection

  • The size and orientation of the ductile iron connection
  • Flange class, if the adapter ends in a flange that meets a ductile iron fitting or valve
  • Required coating, material, bolting, test ports and owner specifications

The line and the site

  • Operating pressure, temperature, media and test requirements
  • Available travel, equipment clearance, excavation and installation access

Measure the pipe in the ground, not only on the drawings

Records do not always match what is in the ground. McWane advises that you may need to expose the existing pipe to determine its type, size, outside diameter and, if possible, its manufacturer before choosing a connection. That matches Koppl's first step: assess the pipe type, failure condition, wire and cylinder configuration, access and system constraints before anything is fabricated.

Published sizes and pressures describe possible operating ranges. They are not approval for a specific project. Koppl's final feasibility call depends on verified line data, field condition, system configuration, media, procedures and the selected equipment.

How Koppl plans a transition on a concrete main

  1. Assess the pipe. Identify the concrete pressure pipe type, failure condition, wire and cylinder configuration, access and system constraints.
  2. Plan isolation. Confirm whether existing valves are reliable or a line stop and bypass strategy is required to control the work area.
  3. Fabricate the solution. Design and build the adapter, butt strap, tee, cross or other custom component the transition needs.
  4. Repair and return. Make the field connection, verify the work, remove temporary isolation equipment as planned and return the system to service.

Isolation matters because a section of concrete main can only come out when the water around it is controlled. When existing valves cannot provide dependable isolation, line stopping can be built into the plan, with a bypass when flow has to continue.

What to send Koppl first

Start with what you know. Gaps are normal. Koppl routes each application for technical review, and that review starts with the actual line and site conditions.

  • Pipe size, material, operating pressure and temperature, and media
  • What you know about the concrete pipe type and its manufacturer, from records or past excavations
  • The new pipe material, size and end connection you need, including flange class if it applies
  • Location, access conditions and schedule
  • The outcome you need, such as replacing a section, adding a valve or tying in a new line
  • Drawings and current site photos, when available

Call Koppl Pipeline Services at the Montebello office, (323) 888-2211. Office hours are Monday through Friday, 6 AM to 4 PM Pacific. For qualified emergency needs, Koppl provides around-the-clock support at the same number.

Plan a concrete pressure pipe project

Frequently asked questions

How easy or difficult is it to connect ductile iron pipe to existing concrete pressure pipe?

It can be done, but it is not a shelf-part job. The PCCP to ductile iron adapter has to match the concrete pipe's type, actual outside diameter, wall and condition on one side and the ductile iron connection on the other. Koppl lists DIP, PVC, HDPE and PCCP transitions among its concrete pressure pipe applications and fabricates transition adapters in-house.

Which concrete pressure pipe types does Koppl support?

Koppl identifies bar-wrapped pipe (B303), prestressed concrete cylinder pipe (L301), and embedded-cylinder pipe (E301) among its supported concrete pressure pipe applications.

Are custom repair fittings available?

KOPPL-KRETE products are fabricated in-house and can include adapters, butt straps, tees, cross fittings, hot tap saddles, and other project-specific components.

Can Koppl isolate the line as part of the repair?

Yes. Line stopping can be incorporated when existing valves do not provide dependable isolation for the affected section.

Keep reading

More from the blog.

Concrete pressure pipe

Concrete Pipe Joint Repair on Water Mains: What to Plan First

A planning guide for utilities and facility managers with a leaking joint on a concrete pressure water main: pipe type, isolation, repair components and what to send Koppl.

Read the post

Project planning

Water lines vs. pipelines: planning municipal water work

How to describe a water project by service and outcome: a new connection, temporary isolation, or a lasting control point, and what to share with Koppl.

Read the post

Facility projects

Pipe freezing in hospital and facility mechanical rooms: when an ice plug beats a drain-down

A failed valve on a riser forces a choice: drain the building or isolate one section. Pipe freezing is the second option. Here is how it works and what to share before the call.

Read the post

From reading to planning

Bring the real line conditions to the conversation.

Share the line size, material, pressure, location, timing, and desired outcome. The field crew can help identify what comes next.